Ks0276 keyestudio MLX90614 Non-contact Infrared Temperature Sensor: Difference between revisions
Keyestudio (talk | contribs) |
Keyestudio (talk | contribs) No edit summary |
||
Line 2: | Line 2: | ||
Keyestudio MLX90614 non-contact infrared temperature sensor is mainly composed of sensor MLX90614. MLX90614 is an infrared non-contact thermometer, and the TO-39 package integrates infrared induction thermoelectric pile detector chip (MLX81101) and signal processing dedicated integrated chip MLX90302. Due to the integration of low noise amplifier, 17-bit analog digital converter and DSP processing unit, the sensor achieves high precision and high resolution measurement. | Keyestudio MLX90614 non-contact infrared temperature sensor is mainly composed of sensor MLX90614. MLX90614 is an infrared non-contact thermometer, and the TO-39 package integrates infrared induction thermoelectric pile detector chip (MLX81101) and signal processing dedicated integrated chip MLX90302. Due to the integration of low noise amplifier, 17-bit analog digital converter and DSP processing unit, the sensor achieves high precision and high resolution measurement. | ||
<br>[[File:Kso276.png|500px|frameless|thumb]]<br> | <br>[[File:Kso276.png|500px|frameless|thumb]]<br> | ||
==Specification== | ==Specification== | ||
Line 57: | Line 59: | ||
} | } | ||
</pre> | </pre> | ||
'''Library Download of Wire:''' [http://www.keyestudio.com/files/index/download/id/1506416358/] | |||
'''Library Download of MLX90614:''' [http://www.keyestudio.com/files/index/download/id/1506416359/] | |||
== Test Reult == | == Test Reult == | ||
Line 67: | Line 73: | ||
'''Figure 2:''' | '''Figure 2:''' | ||
<br>[[File:KS0276(1).png|500px|frameless|thumb]]<br> | <br>[[File:KS0276(1).png|500px|frameless|thumb]]<br> | ||
== Resources == | == Resources == | ||
''' | '''PDF File:''' | ||
http://www.keyestudio.com/files/index/download/id/1500602857/ | http://www.keyestudio.com/files/index/download/id/1500602857/ | ||
'''Library Download of Wire:''' | |||
http://www.keyestudio.com/files/index/download/id/1506416358/ | |||
'''Library Download of MLX90614:''' | |||
http://www.keyestudio.com/files/index/download/id/1506416359/ | |||
Revision as of 17:02, 26 September 2017
Introduction
Keyestudio MLX90614 non-contact infrared temperature sensor is mainly composed of sensor MLX90614. MLX90614 is an infrared non-contact thermometer, and the TO-39 package integrates infrared induction thermoelectric pile detector chip (MLX81101) and signal processing dedicated integrated chip MLX90302. Due to the integration of low noise amplifier, 17-bit analog digital converter and DSP processing unit, the sensor achieves high precision and high resolution measurement.
Specification
- Working voltage:3.3-5V
- Communication way:IIC communication
- Working temperature rang:from -40 to +125 ℃
- Measurement accuracy:±0.5℃(0 to 50℃)
Connection Diagram
Sample Code
/*************************************************** This is a library example for the MLX90614 Temp Sensor Designed specifically to work with the MLX90614 sensors in the adafruit shop ----> https://www.adafruit.com/products/1748 ----> https://www.adafruit.com/products/1749 These sensors use I2C to communicate, 2 pins are required to interface Adafruit invests time and resources providing this open source code, please support Adafruit and open-source hardware by purchasing products from Adafruit! Written by Limor Fried/Ladyada for Adafruit Industries. BSD license, all text above must be included in any redistribution ****************************************************/ #include <Wire.h> #include <Adafruit_MLX90614.h> Adafruit_MLX90614 mlx = Adafruit_MLX90614(); void setup() { Serial.begin(9600); Serial.println("Adafruit MLX90614 test"); mlx.begin(); } void loop() { Serial.print("Ambient = "); Serial.print(mlx.readAmbientTempC()); Serial.print("*C\tObject = "); Serial.print(mlx.readObjectTempC()); Serial.println("*C"); Serial.print("Ambient = "); Serial.print(mlx.readAmbientTempF()); Serial.print("*F\tObject = "); Serial.print(mlx.readObjectTempF()); Serial.println("*F"); Serial.println(); delay(500); }
Library Download of Wire: [1]
Library Download of MLX90614: [2]
Test Reult
Install the above wiring, program the code, and then turn on the serial port monitor to display the current temperature as shown in figure 1; then take a heat source close to the sensor of module board, and the sensor can detect the temperature changes as shown in figure 2.
Resources
PDF File:
http://www.keyestudio.com/files/index/download/id/1500602857/
Library Download of Wire:
http://www.keyestudio.com/files/index/download/id/1506416358/
Library Download of MLX90614:
http://www.keyestudio.com/files/index/download/id/1506416359/
Get One Now
http://www.keyestudio.com/keyestudio-mlx90614-non-contact-infrared-temperature-sensor.html