Ks0169 Keyestudio MAX6675 K-Thermocouple-to-Digital Converter module

From Keyestudio Wiki
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.


Introduction

keyestudio MAX6675 K-Thermocouple-to-Digital Converter module can independently perform functions of signal amplification, cold-junction compensation, linearization, A/D conversion and digital SPI Serial output.
MAX6675 is integrated with cold-junction compensation circuit, with simple 3-bit SPI-Compatible Serial Interface, digitalizing the signal from a type-K thermocouple and output in a 12-bit resolution.
This converter resolves temperatures to 0.25℃, allowing readings as high as +1023.75℃. Operating temperature range is among -20℃~80℃.

thumb


Specification

  • Simple SPI Serial output
  • Temperature measuring range: 0℃~1023.75℃
  • 12-Bit, 0.25°C Resolution
  • Integrated Cold-junction compensation circuit
  • High impedance differential input
  • Open Thermocouple Detection
  • Working voltage: 5V
  • Low power consumption
  • Operating temperature range: -20℃~80℃
  • ESD Protection (Human Body Model)


Resources

https://fs.keyestudio.com/KS0169

Buy From