Ks0264 keyestudio Two-channel Solid State Relay Module

From Keyestudio Wiki
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

Keyestudio Two-channel Solid State Relay Module


thumb


Introduction

Keyestudio two-channel solid state relay is active at LOW level, that is to say, the input control signal is the low level (0-1.5 V), the relay is on; while the input control signal is high level (3-5 V), the relay is off.

Solid State Relay is a new kind of contactless switching device, which is composed of all solid state electronic components.

Compared with the electromagnetic relay, it has higher reliability, with the features of non-contact, long service life, fast speed and less outside interference.
The output control terminal of keyestudio solid-state relay must be connected to the circuit, can only be AC (Alternating Current) , so that the solid state relay can be disconnected normally.


thumb


Performance Parameters

  • Electrical parameters:
Voltage Static Current Working Current Trigger Voltage Trigger Current
Channel 1 DC 5V 0mA 12.5mA 0-1.5V 2mA
Channel 2 DC 5V 0mA 12.5mA 0-1.5V 2mA
  • Output port: AC 100V/2A


Connection Diagram


thumb


Sample Code

 int BASE = 3 ;  //The first relay I/O port
int NUM = 2;   //Total number of relay
void setup()
{
   for (int i = BASE; i < BASE + NUM; i ++) 
   {
     pinMode(i, OUTPUT);   //Set the digital I/O port to output
   }
}

void loop()
{
   for (int i = BASE; i < BASE + NUM; i ++) 
   {
     digitalWrite(i, LOW);    //Set the digital I/O port outputs to "low", that is, gradually open relay
     delay(200);        //delay
   }
   for (int i = BASE; i < BASE + NUM; i ++) 
   {
     digitalWrite(i, HIGH);    //Set the digital I/O port outputs to "high", that is, gradually close relay
     delay(200);        //delay
   }  
}


Result

Wiring as the above diagram, after powered-on, the two-channel solid state relay is first connected and then disconnected successively, repeating alternately.


Resource

  • Code:

https://fs.keyestudio.com/KS0264

  • VIDEO:

http://video.keyestudio.com/ks0264/


Buy from